- Contact Person : Mr. Gao John
- Company Name : Shanghai Heming Electric Co., Ltd.
- Tel : 86-21-69956081
- Fax : 86-21-69956079
- Address : Shanghai,Shanghai,Room 208-210,No. 2,No 808 Liuxiang Road,Jiading Dist,Shanghai
- Country/Region : China
- Zip : 201802
HMWST-D2 type electronic temperature controller socket(Auto switch) with American plug
WST-D2 type electronic temperature controller introduction
The function of each button is clearly, through the relay hige to achieve automatic control, temperature controller will according to the changes and automatically shut off or start the control equipment.
1. Technical specifications:
Temperature measurement range: | 0 degree ~ 70 degree | ||
Sensor: | NTC10K B3435 | ||
Resolution: | 0.5 degree | ||
The control accuracy: | 1 degree | ||
Output type: | relay (contacts capacity of 250 V, 5 A), | ||
Shell size: | 87 mm x 135 mm x 45 mm | ||
Working voltage: | AC85 ~ 242 V frequency 50 Hz / 60 Hz | ||
Types of control: | Heating-type | Cold-type | Automatic heating/cold type |
2. The parameters set operation:
After power instrument by 0-9 in turn shows, detection display is normal, enter the system state after work, display measured values, not changing the set, the original record the data set with automatic control operationChange is accused of temperature setting: It is energized, long press SET key, access to menu mode, according to the corresponding parameters on the adjustment, press " increase " or " reduce " button to change the SET value, " increase " is used to increase the temperature setting, " reduce " used to reduce the temperature setting, Press the "SET" save Settings of data, then the temperature controller to return to control operation. SET the data if not press SET confirmation, the system default 10 seconds to be automatic memory to return working state.Of actual use please do not set the limit higher than the upper.Temperature sensor short-circuit, open circuit fault tip Err.3. Installation: instrument temperature must be held at around -5degree ~ 65degree, the instrument must be placed in no damp and high pressure situation, and ventilation to easy to heat dissipation.
4. Wiring: put the device that need to control inserted in a socket, the power supply must match the manual of the instrument.
5. Parameter (the first group on the left, the right is the second group):
symbols | Description | range | Default value |
H1 | The first group High limit | 1~70degree | 32degree |
L1 | The first group Low limit | 30degree | |
H2 | The second group High limit | 35degree | |
L2 | The second group Low limit | 31degree | |
HC | Cooling/heating switches | 00~70 | 00 |
Note: HC heating/cooling state switch data
00 = heating,01= cooling
HMWST-D2 type electronic temperature controller socket(Auto switch) with American plug