Shanghai Heming Electric Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Gao John
  • Company Name : Shanghai Heming Electric Co., Ltd.
  • Tel : 86-21-69956081
  • Fax : 86-21-69956079
  • Address : Shanghai,Shanghai,Room 208-210,No. 2,No 808 Liuxiang Road,Jiading Dist,Shanghai
  • Country/Region : China
  • Zip : 201802

HMWST-D2 type electronic temperature controller socket(Auto switch) with American plug

HMWST-D2 type electronic temperature controller socket(Auto switch) with American plug
Product Detailed
Related Categories:Temperature Instruments
electronic temperature controller manual switch Auto switch

WST-D2 type electronic temperature controller introduction

The function of each button is clearly, through the relay hige to achieve automatic control, temperature controller will according to the changes and automatically shut off or start the control equipment.

1. Technical specifications:

Temperature measurement range:

0 degree ~ 70 degree

Sensor:

NTC10K    B3435

Resolution:

0.5 degree

The control accuracy:

1 degree

Output type:

relay (contacts capacity of 250 V, 5A),

Shell size:

87 mm x 135 mm x 45 mm

Working voltage:

AC85 ~ 242 V frequency 50 Hz / 60 Hz

Types of control:

Heating-typeCold-typeAutomatic heating/cold type

2. The parameters set operation:

After power instrument by 0-9 in turn shows, detection display is normal, enter the system state after work, display measured values, not changing the set, the original record the data set with automatic control operationChange is accused of temperature setting: It is energized, long press SET key, access to menu mode, according to the corresponding parameters on the adjustment, press " increase " or " reduce " button to change the SET value, " increase " is used to increase the temperature setting, " reduce " used to reduce the temperature setting, Press the "SET" save Settings of data, then the temperature controller to return to control operation. SET the data if not press SET confirmation, the system default 10 seconds to be automatic memory to return working state.Of actual use please do not set the limit higher than the upper.Temperature sensor short-circuit, open circuit fault tip Err.

3. Installation: instrument temperature must be held at around -5degree ~ 65degree, the instrument must be placed in no damp and high pressure situation, and ventilation to easy to heat dissipation. 

4. Wiring: put the device that need to control inserted in a socket, the power supply must match the manual of the instrument.

5. Parameter (the first group on the left, the right is the second group):

symbols

Description

range

Default value

H1

The first group High limit

1~70degree 

32degree

L1

The first group Low limit

30degree

H2

The second group High limit

35degree

L2

The second group Low limit

31degree

HC

Cooling/heating switches

00~70

00

Note: HC heating/cooling state switch data

00 = heating,01= cooling

HMWST-D2 type electronic temperature controller socket(Auto switch) with American plug



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.